Table 1. Transmission Does Not Shift into Forward - Continued.
051
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Voltage 12 to 14.5 Volts - Replace
Transmission Does Not Shift
sure voltage between 12-V cable
transmission controller (WP 0168).
into Forward - Continued
(Figure 8, Item 1) and machine
Install equalizer cover (Figure 7, Item
ground. Voltage should be 12 to
3), washer (Figure 7, Item 4), and bolt
14.5 volts.
(Figure 7, Item 5) on machine.
Install equalizer cover (Figure 7, Item
3), two washers (Figure 7, Item 2), and
bolts (Figure 7, Item 1) on machine.
Install right hose cover (Figure 6, Item
3), washer (Figure 6, Item 5), clamp
(Figure 6, Item 6), spacer (Figure 6,
Item 7), bolt (Figure 6, Item 4), nut
(Figure 6, Item 9), and new lockwasher
(Figure 6, Item 8) on machine.
Install right hose cover (Figure 6, Item
3), washer (Figure 6, Item 2), and bolt
(Figure 6, Item 1) on machine.
Proceed to Test Step 38.
Voltage Greater Than 14.5 Volts -
Replace battery equalizer (WP 0195).
Proceed to Test Step 38.
Figure 8. Equalizer Voltage Test.