TM 5-2420-231-23-1
0057
Table 1. Transmission Has Uncommanded Upshift.
0057
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
NOTE
Transmission Has
Uncommanded Upshift
Always inspect the wiring harness connectors that are involved in the
circuit. Poor connections can often be the cause of a problem in an
electrical circuit. Verify that all connections in the circuit are clean and
secure, and that all connections are in good condition. If a problem with a
connection is found, correct the problem and verify that this malfunction is
active before performing this procedure.
Perform an open or short circuit test at each wiring harness connection to
identify the correct wiring harness to replace.
Perform this test only if the condition is active.
Test Step 1. Verify Transmission
Fluid Level.
Check for correct level of transmission
Transmission Fluid Level Low - Add
fluid (TM 5-2420-231-10) using
transmission fluid to transmission (WP
transmission dipstick (Figure 1, Item 1).
0216).
Proceed to Test Step 5.
Transmission Fluid Level OK -
Proceed to Test Step 2.
Figure 1. Transmission Dipstick.
0057
Test Step 2. Verify Front Display
Panel and Transmission Shift.
NOTE
Refer to How To Use On-Board Diagnostics (WP 0006) to understand the
front display screen indicators.
1. Turn ignition switch to the on posi-
tion (TM 5-2420-231-10).
2. Place powershift lever in the N
position (TM 5-2420-231-10).
3. Observe front display panel (Fig-
T-Lamp Illuminated or Flashing -
ure 2, Item 3) and verify that the T-
Proceed to step 5.
lamp (Figure 2, Item 2) is not illu-
T-Lamp Not Illuminated or Flashing -
Replace transmission (WP 0213).