Figure 16. Flowmeter.
Figure 18. Flowmeter Inlet Hose.

Tractor, Wheeled, Industrial Backhoe Loader Nsn 2420-01-532-3399
Page Navigation
  1078    1079    1080    1081    1082  1083  1084    1085    1086    1087    1088  
img
TM 5-2420-231-23-1
0086
WARNING
DO NOT disconnect or remove any hydraulic system line or fitting unless the engine is
shut down and hydraulic system pressure has been relieved. Tighten all connections
before applying pressure. Escaping hydraulic fluid under pressure can penetrate the skin,
causing injury or death to personnel.
Allow hydraulic system to cool before performing procedure. Hot metal parts can cause
severe burns. Wear eye, hand, and skin protection when working with heated parts.
Hydraulic oil is very slippery. Immediately wipe up any spills.
Always know location of all other personnel in area. Warn them before operating the BHL.
Always keep all other personnel away from area.
Failure to follow these warnings may result in injury or death to personnel.
CAUTION
Plug and cap all hoses and fittings to prevent contamination. Failure to follow this caution
may result in damage to machine.
NOTE
Tag and mark hydraulic hose connections to aid in installation.
Use a copy of flowmeter checksheet (Figure 71 and Figure 72) to record information for
the following tests.
LARGE HYDRAULIC OIL PUMP EFFICIENCY READING
0086
1. Turn engine off and position ignition switch to the on position.
2. Enable pilot control switch (TM 5-2420-231-10).
3. Move manual control lever and backhoe joysticks to remove residual hydraulic pressure (TM 5-2420-231-10).
4. Turn ignition switch to the off position (TM 5-2420-231-10).
0086-16