TM 5-2420-231-23-1
0086
BACKHOE LOAD SENSE RELIEF VALVE TEST CONTINUED
7. Remove two screws (Figure 14, Item 3) and screen (Figure 14, Item 4) from hydraulic reservoir
(Figure 14, Item 5).
8. Insert outlet hose (Figure 14, Item 2) until it touches bottom of hydraulic reservoir (Figure 14, Item 5) and
secure hose in place.
Figure 14. Hydraulic Reservoir.
0086
9. Connect inlet hose (Figure 15, Item 1) and outlet hose (Figure 15, Item 2) to flowmeter (Figure 15, Item 3).
Figure 15. Flowmeter Connections.
0086