BACKUP ALARM REPLACEMENT
Figure 3. Swing Cushion Valve.

Tractor, Wheeled, Industrial Backhoe Loader Nsn 2420-01-532-3399
Page Navigation
  686    687    688    689    690  691  692    693    694    695    696  
img
.
TM 5-2420-231-23-2
0186
REMOVAL
0186
1. Disconnect two tubes (Figure 1, Item 1) from swing cushion valve (Figure 1, Item 5).
2. Remove two bolts (Figure 1, Item 2), washers (Figure 1, Item 3), and nuts (Figure 1, Item 4) from swing
cushion valve (Figure 1, Item 5) and position swing cushion valve aside.
Figure 1. Swing Cushion Valve.
0186
NOTE
Tag and mark wires to aid in installation.
3. Disconnect electrical connector (Figure 2, Item 1).
4. Remove two bolts (Figure 2, Item 2), washers (Figure 2, Item 3), and backup alarm (Figure 2, Item 4) from
machine.
Figure 2. Backup Alarm.
0186
END OF TASK