TM 5-2420-231-23-3
0235
REMOVAL
0235
NOTE
The procedure for loader bucket cylinder tube removal and replacement is identical for
left-hand and right-hand cylinder tubes. Left-hand loader bucket cylinder tubes are shown
in this procedure.
1. Remove clamp (Figure 1, Item 7) and resilient mount (Figure 1, Item 6) from loader bucket cylinder
(Figure 1, Item 5).
2. Disconnect tube (Figure 1, Item 1) from fitting (Figure 1, Item 2).
3. Disconnect tube (Figure 1, Item 10) from fitting (Figure 1, Item 9).
4. Loosen nut (Figure 1, Item 3) and remove fitting (Figure 1, Item 2) and O-ring (Figure 1, Item 4) from loader
bucket cylinder (Figure 1, Item 5). Discard O-ring.
5. Remove fitting (Figure 1, Item 9) and O-ring (Figure 1, Item 8) from loader bucket cylinder (Figure 1, Item 5).
Discard O-ring.
6. Repeat steps 1 through 5 for right cylinder tubes.
Figure 1. Left Loader Bucket Cylinder.
0235