Figure 5. Heat Exchanger.
Figure 7. Blower Housing.

Tractor, Wheeled, Industrial Backhoe Loader Nsn 2420-01-532-3399
Page Navigation
  958    959    960    961    962  963  964    965    966    967    968  
img
.
TM 5-2420-231-23-3
0352
INSTALLATION CONTINUED
NOTE
Remove plugs and caps from hoses and fittings.
Install lines as tagged and marked during removal.
2. Install heat exchanger (Figure 6, Item 1) on blower housing (Figure 6, Item 2).
3. Remove plugs and caps from heater tubes (Figure 6, Item 6) and heat exchanger (Figure 6, Item 1).
4. Connect two heater hoses (Figure 6, Item 5) to heater tubes (Figure 6, Item 6).
5. Connect two heater hoses (Figure 6, Item 5) to heat exchanger (Figure 6, Item 1).
6. Slide four heater clamps (Figure 6, Item 4) to ends of two heater hoses (Figure 6, Item 5).
7. Install duct tape (Figure 6, Item 3) on blower housing (Figure 6, Item 2) and heat exchanger (Figure 6, Item 1).
Figure 6. Blower Housing.
0352
0352-5