Figure 2. Heater Control Valve Connection.
A/C EVAPORATOR AND EXPANSION VALVE REPLACEMENT

Tractor, Wheeled, Industrial Backhoe Loader Nsn 2420-01-532-3399
Page Navigation
  988    989    990    991    992  993  994    995    996    997    998  
img
.
TM 5-2420-231-23-3
0357
INSTALLATION CONTINUED
NOTE
Locking tabs on heater control must be compressed against cable casing.
3. Install control cable (Figure 3, Item 3) on heater control (Figure 3, Item 4).
4. Install cable casing (Figure 3, Item 1) in locking tabs (Figure 3, Item 2).
Figure 3. Heater Control Connection.
0357
END OF TASK
FOLLOW-ON TASKS
0357
Install instrument panel right-side cover (WP 0176).
END OF TASK
END OF WORK PACKAGE
0357-3/(4 blank)