TM 5-3805-255-14
0047
REMOVAL
00047
CAUTION
Tag and identify all hoses, lines, and ports for ease of installation. Cap all hose flanges to
prevent contamination and leaks. Open valve and pump ports should be plugged. Do not
use rag to plug ports. Failure to follow this caution may result in damage to equipment.
1. Remove hose clamp (Figure 1. Item 7) and hose (Figure 1. Item 6) from converter housing (Figure 1. Item 8).
2. Disconnect breather tube (Figure 1. Item 1) from elbow on top of converter housing (Figure 1. Item 8).
3. Disconnect lines (Figure 1, Items 2, 3, 4, and 5) from converter housing (Figure 1. Item 8).
Figure 1. Cooler Lines and Tube Removal.
0047
NOTE
Mark the converter drive ring and rotating housing for ease of assembly.
4. Remove propshaft from converter housing (WP 0049).
5. Attach suitable lifting device to converter housing (Figure 2, Item 3).
6. Remove 12 bolts (Figure 2, Item 2) and 12 lockwashers (Figure 2, Item 1) from converter housing (Figure 2,
0047-2