TM 5-3805-255-14
0061
INSTALLATION CONTINUED
Left Treadle Valve
00061
1. Install left treadle valve (Figure 19, Item 9), three bolts (Figure 19, Item 6), new lockwashers (Figure 19,
Item 8), and nuts (Figure 19, Item 7) on floorboard (Figure 19, Item 21).
2. Install tee fittings (Figure 19, Items 2 and 13) on left treadle valve (Figure 19, Item 9).
3. Install elbow fittings (Figure 19, Items 5, 17, 18, and 19) on left treadle valve (Figure 19, Item 9).
4. Install left check valve (Figure 19, Item 2) or elbow (Figure 19, Item 18).
5. Connect tube (Figure 19, Item 20) to elbow (Figure 19, Item 19).
6. Connect tube (Figure 19, Item 16) to elbow (Figure 19, Item 17).
7. Connect hoses (Figure 19, Items 14 and 15) to tees (Figure 19, Items 12 and 13).
8. Connect tubes (Figure 19, Items 10 and 11) to tees (Figure 19, Items 13 and 12).
9. Connect tube (Figure 19, Item 4) to elbow (Figure 19, Item 5).
10. Connect hoses (Figure 19, Items 1 and 3) to left check valve (Figure 19, Item 2).
Figure 19. Left Treadle Valve.