TM 5-3805-258-10
Measure the fuel level. Fill the fuel tank
after each day of operation to help prevent
condensation in the tank.
Inspect the wheel brakes for oil leaks
Observe the water level, if necessary, add
distilled water to bring the electrolyte level
the bottom of the fill opening.
Alternator Belts
Every 100 Service Hours or 2 Weeks
I n s p e c t f o r l o o s e , m i s s i n g,
o r w o r n d r i v e b e l t s .
Batteries
Air Intake System
WARNING
Batteries give off flammable fumes that
c a n e x p l o d e .
Electrolyte is an acid and can cause per-
sonal injury if it contacts skin or eyes.
Do not smoke when observing battery
electrolyte level.
Always wear protective glasses when
working with batteries.
36
If air cleaner indicator locks in RED position,
notify Organizational Maintenance.