9 5 0 B O P E R A T O R ’ S S T A T I O NTM 5-3805-258-24-1E L E C T R I C A L T R O U B L E S H O O T I NGTROUBLESHOOTINGLow Fuel Level Indicator1. At the fuel tank, remove the T/O wire from the Fuel Level Switch (sensor).Use an 8S4627 Circuit Tester to check for continuity across the switch. Theremust be continuity if the fuel level is more than 10% of capacity.ContinuityNo ContinuityThe switch is good. Go to Step 2.Replace the switch.2. Check continuity from switch to machine ground with an 8S4627 CircuitTester.ContinuityNo ContinuityGround connection is good. Go to Step 3.Repair or replace harness or fasten a ground wirefrom the switch to machine ground.3. Connect the T/O wire to the switch (sensor) again. Disconnect the harnessplug from the operator panel. Check for continuity between Sockets 2 and 14 inthe harness plug with an 8S4627 Circuit Tester. Socket 2 is the groundconnection for the operator panel and Socket 14 goes to the fuel level switch.ContinuityNo ContinuityThe harness is good. Replace the operator panel.Use the electrical schematic or simplified schematicto find the harness with an open wire. Repair orreplace the harness.4-117