9 5 0 B O P E R A T O R S S T A T I O N
TM 5-3805-258-24-1
E L E C T R I C A L T R O U B L E S H O O T I N G
L i f t K i c k o u t S c h e m a t ic
Troubleshooting the Lift Kickout Circuit on the Machine
If the kickout does not work, do the tests that follow in order:
A. Check the kickout fuses (found in the right hand side panel of the
operators cab).
B. Check the distance between the magnet and the switch box. The dis-
tance must be 6.4 to 9.0 mm (.25 to .35 in.).
M a g n e t t o S w i t c h A d j u s t m e n t
C. Move the lift arms so the magnet is not close to the switch box. With the
power key switch turned ON, move another magnet close to the
switch to see if this causes the solenoid to activate. If the magnet causes
the solenoid to activate, install a new magnet on the machine.
4-129