TM 5-3805-258-24-1Every 100 Service Hours or 2 WeeksHYDRAULIC SYSTEM1. The machine must be level, the oilwarm and the engine running at low idle.Lubricate 1 fitting in the lower bucket link.2. Lock the transmission control lever inNEUTRAL. Apply the parking brake. Lowerthe bucket with slight down pressure.BUCKET UPPER PIVOT PIN3. Inspect the oil level in the hydraulictank sight gauge. Maintain the oil levelbetween the ADD and the FULL mark inthe sight gauge.1-43