3-5. TROUBLESHOOTING TABLE (CONT)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3. ENGINE STARTS BUT WILL NOT RUN (CONT)
Step 3. (Continued]
a. If fuel shut off lever
b. If fuel shut off lever
maintenance.
moves back and forth, go to step 4 below.
does not move, notify organizational
Step 4.
Tell assistant to push fuel SHUT OFF control all the way in.
Check at fuel injection pump that fuel shut off lever moves behind
fuel injection pump.
Tell assistant to start engine while you grasp fuel shut off lever
and move it towards rear of loader.
Engine should start.
a. If engine starts, notify organizational maintenance to adjust
SHUT OFF control.
b. If engine does not start, go to step 5 below.
Step 5.
Check if restriction indicator red band is
visible.
a.
b.
If red band is visible, press
reset button on top of indica-
tor and check that red band
disappears from view. (If red
band does not disappear from
view, notify organizational
maintenance that restriction
indicator is defective.)
Crank engine and check if red
band reappears; if red band is
visible,
service air cleaner.
If red band is not visible, go to step 6 below.
Step 6.
Check fuel injector lines for fuel leaks.
a. If fuel injector lines are leaking, notify organizational
maintenance.
3-10