TM 5-3805-262-10
3-5. TROUBLESHOOTING TABLE (CONT)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. ENGINE HARD TO START OR WILL NOT START (CONT)
Step 7.
Unlock and remove engine front left side panel.
Check cable connections to starter motor for looseness.
a. If cable connections at starter motor are loose, notify organi-
zational maintenance.
b. If cable connections are not loose, go to step 8 below.
Step 8.
Check for incorrect or contaminated fuel in fuel tank.
Notify organizational maintenance.
3. ENGINE STARTS BUT WILL NOT RUN
Step 1.
Check fuel supply.
a. If fuel supply is low, fill fuel tank with correct grade of
fuel.
b. If fuel supply is okay, go to step 2 below.
Step 2.
Check that SHUT OFF control is pushed all the way in.
a. If SHUT OFF control is not pushed completely in, push in com-
pletely.
3-8