TM 5-3805-262-10
3-5. TROUBLESHOOTING TABLE (CONT)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3. ENGINE STARTS BUT WILL NOT RUN (CONT)
Step 6. (Continued)
b. If fuel injector lines are not leaking, go to step 7 below.
Step 7.
Check for incorrect or contaminated fuel in fuel tank (notify organ-
izational maintenance).
Notify organizational maintenance.
4. ENGINE DOES NOT FIRE CORRECTLY (LOW AND HIGH RPM)
Step 1.
Check if WATER TEMP gage pointer is in
green area of gage.
a.
b.
If WATER TEMP gage pointer is not
in green area of gage, operate en-
gine at approximately 1000 rpm un-
til gage pointer indicates in
green area.
If after several minutes, WATER
TEMP gage pointer does not start
to move into green area, notify
organizational maintenance (ther-
mostat must be tested).
If WATER TEMP gage pointer is in green area of gage, go to step
2 below.
3-11