TM 5-3805-262-10
2-16. ADJUSTMENTS (CONT)
a. Bucket Height Control Adjustment (Cont).
(8)
(9)
(lo)
(11)
Put LIFT ARM control lever in RAISE position.
Magnetic detent in control valve will hold
LIFT ARM control in RAISE position until
bucket is at height set in step (3) above.
Check if bucket is at desired dump height.
Small adjustments can be made by pushing
bucket height control lever down to increase
dump height or lifting bucket height control
lever to decrease dump height.
Lower bucket to ground using LIFT ARM control lever in LOWER position.
Return LIFT ARM control lever to NEUT. after bucket is on ground.
Turn off engine.
b. Return-To-Dig Control Adjustment.
This control automatically returns bucket
to digging position.
It consists of a rod, tube, and a microswitch mounted on right
bucket tilt cylinder assembly.
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
With engine operating and
loader parked on a level
surface, lower bucket to ground
using LIFT ARM control lever in
LOWER .
Put LIFT ARM control lever in FLOAT position.
Use BUCKET control lever in DUMP position to position
bucket at desired digging angle then return BUCKET
control lever to NEUT. position.
Turn off engine.
Loosen two nuts and capscrews on clamps securing tube and microswitch to
right bucket tilt cylinder assembly.
Move tube off rod until microswitch roller is not touching rod.
Move tube onto rod until microswitch roller is touching rod and you hear
a noise from microswitch.
Tighten two capscrews and nuts on clamps. Dont let tube and microswitch
move.
2-46