TM 5-3805-262-102-16. ADJUSTMENTS (CONT)a. BucketHeightControlAdjustment(Cont).(8)(9)(lo)(11)Put LIFT ARM control lever in RAISE position.Magnetic detent in control valve will holdLIFT ARM control in RAISE position untilbucket is at height set in step (3) above.Check if bucket is at desired dump height.Small adjustments can be made by pushingbucket height control lever down to increasedump height or lifting bucket height controllever to decrease dump height.Lower bucket to ground using LIFT ARM control lever in LOWER position.Return LIFT ARM control lever to NEUT. after bucket is on ground.Turn off engine.b. Return-To-DigControlAdjustment.This control automatically returns bucketto digging position.It consists of a rod, tube, and a microswitch mounted on rightbucket tilt cylinder assembly.(1)(2)(3)(4)(5)(6)(7)(8)With engine operating andloader parked on a levelsurface, lower bucket to groundusing LIFT ARM control lever inLOWER .Put LIFT ARM control lever in FLOAT position.Use BUCKET control lever in DUMP position to positionbucket at desired digging angle then return BUCKETcontrol lever to NEUT. position.Turn off engine.Loosen two nuts and capscrews on clamps securing tube and microswitch toright bucket tilt cylinder assembly.Move tube off rod until microswitch roller is not touching rod.Move tube onto rod until microswitch roller is touching rod and you heara noise from microswitch.Tighten two capscrews and nuts on clamps. Don’t let tube and microswitchmove.2-46