TM 5-3805-262-102-16. ADJUSTMENTS (CONT)b. Return-To-Dig Control Adjustment (Cont).(9)(lo)(11)position and raise bucket to fullUse LIFT ARM control lever in RAISE _height or height set with bucket height control and dump bucket usingBUCKET control lever in DUMP position.Put BUCKET control lever in CROWD position and LIFT ARM control lever inFLOAT position. Bucket will roll back and lower to ground. Return LIFTARM control lever to NEUT. position.Check digging angle of bucket. If desired digging angle of bucket is notobtained, repeat steps (2) through (11) above.2-17. OPERATING PROCEDURESDon’t use jumper cables connected to battery terminals to start engineor charge batteries. Always use slave receptacle. Failure to do so couldcause serious injury due to batteries exploding caused by improper con-nection of jumper cables to battery terminals.Starting the Engine.a.Before starting engine, check and be sure that transport/service link isin released position. Failure to do so will cause loss of steering con-trol which may result in serious injury or death and extensive propertydamage.(1) Release transport/service link by removing two clips securing pins. Pulltie bar pins from chassis. Remove transport/service link and install inreleased position as shown. Reinstall pins and secure with clips.2-47