TM 5-3805-262-20
INSTALLATION ( SHEET 1 OF 2)
(1)
I f n e c e s s a r y,
install four clip nuts (25) in cab by pushing onto sheet
metal at locations noted during removal.
( 2 ) I f r e m o v e d ,
install new filler strip (24) by removing protective paper
backing and pressing adhesive side of filler strip firmly onto top edge
of instrument panel (23).
(3) Position instrument panel (23) in cab and tilt as necessary for access to
terminals at rear of panel.
(4) Connect wiring harness connectors to instrument panel components as fol-
lows :
(a) Connect ignition switch connector (18) by grasping with fingers, alining
with ignition switch terminals, and pushing firmly.
(b) Connect vehicle lights switch connector (19) by grasping with fingers,
alining connector slot with switch tab, pushing firmly, and turning con-
nector nut clockwise.
(c) Connect eyelet terminals (20) as tagged using attaching nuts or screws
noted during removal.
(d)
(5)
(6)
(7)
( 8)
(9)
( l 0)
(11)
(12)
(13)
(14)
(15)
Connect spade terminals (21) and bullet terminals (22) as tagged by
grasping with fingers, alining, then firmly pushing them together.
Secure instrument panel (23) to cab using four screws (16) and lock wash-
e r s ( 1 7 ) .
At parking brake valve,
install and tighten parking brake switch (15).
Connect wiring harness terminal (14) to parking brake switch (15) termi-
nal using screw (13).
At parking brake valve, install and tighten air pressure switch (12).
Connect two wiring harness terminals (10 and 11) to air pressure switch
(12) terminals using two screws (9).
Install resistor (8) by pushing into long half of fuseholder (7) .
Assemble fuseholder (7) halves by grasping both in your fingers, alining,
then firmly pushing them together and twisting clockwise.
Raise and hold parking brake valve in position at instrument panel and
secure using nut (6).
Position knob (5) on parking brake valve stem, aline hole in knob with
h o l e i n s t e m , a n d i n s t a l l r o l l p i n ( 4 ) u s i n g p l i e r s.
Raise and hold end of fuel shutoff cable (3) in position at instrument
panel and secure using nut (2).
Install handle (1) by turning clockwise on threaded shaft of fuel shutoff
c a b l e ( 3 ).
5-63