TM 5-3805-262-20
REMOVAL (SHEET 4 OF 5)
(r) At flow switch (24) located at bottom of hydraulic oil cooler, loosen
and disconnect fitting at other end of hose (5); remove hose (5) from
l o a d e r.
(s) Remove connector (22).
(t) Grasp terminal (23) and wiring harness lead then pull both apart to dis -
connect them. Repeat for remaining two terminals (23).
(u) Remove flow switch (24) and, if necessary, elbow (25) from bottom port
o f h y d r a u l i c o i l c o o l e r.
(v) At right side of hydraulic pump, tag, loosen, and disconnect tube (7)
fitting from fitting (27). Remove tube (7) from loader.
( w ) T a g , l o o s e n , a n d d i s c o n n e c t h o s e ( 2 6 ) f i t t i n g f r o m f i t t i n g ( 2 7 ) ; i n s t a ll
plug in hose (26) fitting to prevent entry of foreign matter.
( x ) I f n e c e s s a r y , r e m o v e f i t t i n g ( 2 7 ) , d u s t c a p ( 2 8 ) , n i p p l e ( 2 9 ) , f i t t i ng
(30), check valve (31), elbow (32), and 0-ring (33). Discard 0-ring
(33).
8-19