TM 5-3805-262-34
4-3. TRANSMISSION MAINTENANCE (CONT)
b. Torque Converter Housing (Cont).
REASSEMBLY
(1)
(2)
(3)
(4)
(5)
(6)
If
(SHEET 1 OF 4)
Put drive gear and shaft (29)
in hydraulic press. Position
bearing (28) on drive gear and
shaft and press bearing onto
drive gear and shaft using
2-1/4 inches inside diameter
sleeve.
Lubricate new seal (24) using
lubricating oil and install in
groove in hub of drive gear and
shaft (29).
Install thrust race (27), thrust bearing (26),
drive gear and shaft (29).
Put bearing (22) in hydraulic
press using a 2-1/4 inches
inside diameter by 9 inches
long sleeve to support it. Put
drive gear and shaft (23) in
bearing and sleeve. Press drive
and thrust race (25) on
gear and shaft into bearing.
Lubricate new seal (21) using
lubricating oil. Install seal
in groove on hub of drive gear
and shaft (23).
If removed, position valve (18)
and converter pressure regula-
tor spring (19) on valve guide
pin (16). Press valve guide pin
into upper torque converter
housing valve bore until valve
guide pin protrudes 1.16 to
1.18 inches above surface of
valve (18).
NOTE
press fit of valve guide pin (16) is not satisfactory, clean and
apply thread sealant to bore and valve guide pin. Allow thread sealant
to cure for two hours at room temperature after pressing valve guide pin
into bore.
4-124