TM 5-3805-262-34LEGEND1. Setscrew2. Setscrew3. Lubrication fitting4. Lock pin5. Bearing and seal6. HousingCLEANING, INSPECTION, AND REPAIRDry cleaning solvent P-D-680 used to clean parts is toxic and flammable.Wear protective goggles and gloves and use only in a well ventilatedarea. Avoid contact with skin, eyes and clothes and don’t breathevapors. Do not use near open flame or excessive heat and donut smokewhen using it. Failure to do so could cause serious injury. If you be-come dizzy while using cleaning solvent, get fresh air and medicalattention immediately. If contact with skin or clothes is made, flushwith large amounts of water. If contact with eyes is made, wash eyeswith water and get medical aid immediately.(1)(2)(3)(4)(5)Clean all parts except bearing and seal (5) using cleaning solventP-D-680. Dry using clean cloths.Wipe exterior of bearing and seal (5) using clean cloth moistened withcleaning solvent P-D-680. Don’t saturate bearing and seal with cleaningsolvent.Inspect housing (6) for cracks, breaks, chipping, or other damage. Re-place if necessary.Inspect bearing and seal (5) for cracks, deformation, or other damage.Check that bearing rotates smoothly without noticeable binding. Replaceif any defects are seen.Inspect remaining parts for cracks, breaks, deformation, distortion, orthread damage. Replace as necessary.3-353