TM 5-3805-262-34REASSEMBLY OF AIR CHAMBER(1)(2)(3)(4)(5)(6)(7)(8)If removed, install plug (28) in cover (23).Put housing (27) and clamps (22) in hy-draulic press.Install spring (26) in housing(27). Be sure long end of sprigoes through hole in housing.Install piston (25), diaphragm(24), and cover (23) on housin(27).Aline match marks on housing(27), cover (23), and clamps(22). Operate hydraulic pressto push cover (23) againsthousing (27) to compressspring (26).Put two clamps (22) in position to fasten cover (23) to housing (27).Install and tighten two capscrews (21) and nuts (20).Remove air chamber from hydraulic press.3-435