FAN HOUSING ACCESS DOOR
COOLANT OVERFLOW TANK

Loader, Light, Scoop: 2.5 Cubic Yard Multipurpose Clamshell Bucket 4-Wheel Drive Model 924G
Page Navigation
  50    51    52    53    54  55  56    57    58    59    60  
img
. .
TM 5-3805-290-10
DESCRIPTION AND USE OF OPERATOR CONTROLS AND INDICATORS - CONTINUED
0004 00
TRANSMISSION OIL LEVEL SIGHT GAGE
0004 00
1.
Sight gage is located on left side of machine under
steps.
2.
Transmission oil level sight gage indicates level of oil
in transmission.
3.
Maintain oil level between LOW mark and HIGH
mark when transmission is warm and engine running.
Maintain oil level to top of sight gage when transmis-
sion is cool and engine not running.
4.
Refer to WP 0012 00 for instructions on adding oil to
transmission.
427-B1336
CIRCUIT BREAKERS AND ARCTIC HEATER FUSE
0004 00
1.
Main Circuit Breaker. Located on left side of engine
enclosure. This is a 60-amp circuit breaker. Press but-
ton to reset. If circuit is operating properly, button will
remain depressed.
Alternator Circuit Breaker. Located on left side of
2.
engine enclosure. This is a 90-amp circuit breaker.
Press button to reset. If circuit is operating properly,
button will remain depressed.
Arctic Heater Fuse (If Equipped). Located on left
3.
side of engine enclosure. This 15-amp fuse protects
arctic heater circuits. Fuse is only on arctic operation
machine.
427-B0534
0004 00-31