COOLANT OVERFLOW TANK
ETHER STARTING AID SYSTEM

Loader, Light, Scoop: 2.5 Cubic Yard Multipurpose Clamshell Bucket 4-Wheel Drive Model 924G
Page Navigation
  52    53    54    55    56  57  58    59    60    61    62  
img
. .
TM 5-3805-290-10
DESCRIPTION AND USE OF OPERATOR CONTROLS AND INDICATORS - CONTINUED
0004 00
ENGINE OIL LEVEL DIPSTICK - CONTINUED
0004 00
3.
Maintain oil level within crosshatched area (A) on
dipstick. It takes 2 qt (1.9 L) to fill from lowest point
on crosshatched area.
4.
Refer to WP 0012 00 for instructions on adding oil to
engine.
427-B1998
FUEL/WATER SEPARATOR DRAIN VALVE
0004 00
1.
Fuel/water separator is located in engine compartment
on right side of machine.
2.
Turn drain valve counterclockwise (to the left) to drain
water and sediment from fuel/water separator.
3.
After draining, turn fuel/water separator drain valve
clockwise (to the right) to close.
427-B0541