TM 5-3805-290-10
OPERATION UNDER UNUSUAL CONDITIONS - CONTINUED
0006 00
SLAVE STARTING MACHINE
0006 00
WARN I N G
When slave starting machine:
Use NATO slave cable that DOES NOT have loose or missing insulation.
DO NOT proceed if cable is not available.
DO NOT use civilian-type jumper cables.
DO NOT allow "dead" and "live" machines to come in contact with each other at any time during
slave starting.
Failure to follow these warnings may cause injury or death to personnel.
CAU T I ON
Under no circumstances can machine be started by being towed or pushed. Failure to follow this cau-
tion will damage transmission.
N OT E
If machine other than another 924G is used to slave start loader, refer to Operator's Manual for that
machine for any special slave starting procedures.
1.
Ensure battery disconnect switch is in OFF position on both "dead" and "live" machine.
N OT E
NATO slave receptacle is located at left-rear of machine.
2.
Remove cover and connect NATO slave cable to
receptacle on "dead" machine.
427-B1824
3.
Remove cover and connect other end of NATO slave cable to receptacle on "live" machine.
4.
Place battery disconnect switch on "dead" machine in ON position.
5.
Start engine of "live" machine and run at a speed just above idle.