TM 5-3805-290-10
TROUBLESHOOTING PROCEDURES - CONTINUED
0010 00
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
BRAKES - SERVICE AND PARKING/EMERGENCY - CONTINUED
WARN I N G
5.
Service Brakes
Do
Not
Operate
Correctly.
Park machine on level ground, stop engine, and lower
work tool to ground to prevent injury to operator and/
or severe damage to machine.
If emergency use of parking brake is required due to
service brake failure, ensure that brakes are inspected
and repaired, if necessary, before resuming machine
operation. Injury or death to personnel or damage to
equipment could result from improperly or non-func-
tioning brakes.
1. Check for mud or dirt under
Clean mud or dirt from under brake
brake pedals.
pedals. If problem still exists, go to
test step 2.
2. Stop machine and shut down
Notify Unit Maintenance.
WARN I N G
6.
Service Brakes
Do
Not
Release
Correctly.
Park machine on level ground, stop engine, and lower work
tool to ground to prevent injury to operator and/or severe
damage to machine.
1. Check for mud or dirt under
Clean mud or dirt from under brake
brake pedals, causing pedals to
pedals. If problem still exists, go to
stick.
test step 2.
2. Ensure parking brake is
Disengage parking brake. If problem
still exists, go to test step 3.
3. Stop machine and shut down
Notify Unit Maintenance.
CHARGING SYSTEM
Electrical System Alert Indicator Comes 1. Check that 60-amp main circuit Reset circuit breakers. If problem still
breaker and 90-amp alternator exists, go to test step 2.
On.
circuit breaker are not tripped
2. Check for loose or broken V-
If loose or broken V-belts are found,
belts.
or if V-belts are OK and problem still
exists, notify Unit Maintenance.