TM 5-3805-290-10
TROUBLESHOOTING PROCEDURES - CONTINUED
0010 00
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ENGINE - CONTINUED
WARN I N G
DO NOT smoke or permit any open flame in area of
machine while you are servicing fuel system. Be sure
hose nozzle is grounded against filler tube during refuel-
ing to prevent static electricity. Failure to follow this
warning may result in injury or death to personnel, or
damage to equipment.
Operating personnel must wear fuel-resistant gloves
when handling fuels. If exposed to fuel, promptly wash
exposed skin and change fuel-soaked clothing.
ALWAYS stop engine prior to refueling. If equipped
with an arctic cold weather starting aid system, turn
engine coolant heater off.
N OT E
Ensure portable fire extinguisher is within reach prior to
refueling.
Engine Cranks but Fails to Start: 1. Check fuel tank gage with
If indication is empty, add fuel (WP
2.
engine start switch ON.
Operating Temperature -25 to -40F (-32
test step 2.
to -40C).
2. Check for blown arctic heater
If fuse is bad, request a replacement
fuse from Unit Maintenance. If fuse
is good, or problem still exists, go to
test step 4.
3. Check for blown start aid fuse
If fuse is bad, request a replacement
fuse from Unit Maintenance. If
engine still will not start, notify Unit
Maintenance.
4. Check for missing or empty
If ether canister is missing or empty,
notify Unit Maintenance.
If plugged in, notify Unit
Maintenance.