TM 5-3805-290-23-1
HOW TO USE ON-BOARD DIAGNOSTICS - CONTINUED
0005 00
FAILURE MODE IDENTIFIERS (FMIS) - CONTINUED
Table 1. Detailed FMI Explanation - Continued.
FMI
DESCRIPTION
EXPLANATION
12
Bad Device or
Electronic control sends a signal and expects a response but receives no response or
Component.
the response is incorrect. Some possible causes of an FMI 12 diagnostic code are:
There is a failure of electronic control.
There is a failure on the data link.
There are one or more controls with mismatched software.
13
An electrical signal is not within limits for a specific mechanical condition. Some
possible causes of an FMI 13 diagnostic code are:
Data are out of range.
14
This code is not active.
15
This code is not active.
16
Parameter Not
Control does not support the requested parameter.
Available.
17
Module Not
Control does not respond to a request for data.
Responding.
18
Sensor Supply Failure.
The sensor power supply in a control has failed.
19
Condition Not Met.
Conditions defined by the software were not met.
20
This code is not active.
END OF WORK PACKAGE