  560    561    562    563    564  565  566    567    568    569    570  
img
.
TM 5-3805-290-23-1
TROUBLESHOOTING WITH A DIAGNOSTIC CODE - CONTINUED
0009 00
Table 2. Machine Control System - Continued.
(MID 081)
TEST OR INSPECTION
CORRECTIVE ACTION
CID FMI CODE
1. If each resistance measurement is
2. Check harness.
0490 04 -
greater than 5,000 Ohms, replace
(a) Turn battery disconnect switch and
Cont.
machine ECM (WP 0052 00).
engine start switch to OFF position
2. If one or more resistance
(TM 5-3805-290-10).
measurements is less than 5.0 Ohms,
(b) Wiring harness remains disconnected
short is between J2-58 (wire E917 WH)
from switch.
and circuit with lowest resistance, or
(c) Disconnect wiring harness
between J2-59 (wire E918 GN) and
connector(s) from machine ECM (WP
circuit with lowest resistance. Replace
0052 00).
wiring harness in question (WP 0169
(d) Measure resistance between contacts
00 thru WP 0175 00).
J2-58 (wire E917 WH) and J2-59 (wire
E918 GN) of wiring harness to all
contacts used in ECM wiring harness
connectors.
3. Check implement lockout switch operation. 1. If resistance from contact 5 (wire 202
(a) Wiring harness remains disconnected
BK) to contact 4 (wire E918 GN) is less
from switch.
than 5.0 Ohms and resistance from
(b) Connect one lead from multimeter to
contact 5 (wire 202 BK) to contact 6
contact 5 (wire 202 BK) of switch
(wire E917 WH) is greater than 5,000
harness connector.
Ohms, go to Test 4.
(c) Connect other lead from multimeter to  2. If resistance measurements do not
contact 6 (wire E917 WH) of switch
differ, replace implement lockout
harness connector.
switch (WP 0049 00).
(d) Measure resistance between contact 5
(wire 202 BK) and contact 6 (wire
E917 WH).
(e) Disconnect lead from contact 6 (wire
E917 WH) and connect lead to contact
4 (wire E918 GN).
(f) Measure resistance between contact 5
(wire 202 BK) and contact 4 (wire
E918 GN).
0009 00-68