TM 5-3805-290-23-1
PREPARATION FOR STORAGE OR SHIPMENT - CONTINUED
0208 00
PREPARATION FOR SHORT-TERM STORAGE - CONTINUED
8.
Remove batteries (WP 0077 00) and clean batteries, clamps, supports, retainers, and battery box using a Brush, acid
swabbing (Item 16, WP 0205 00) and a solution of 1/2 lb (0.23 kg) of Sodium bicarbonate, technical (Item 50, WP 0206
00), to 1 gal. (3.8 L) of water. Flush with clean water and dry (TM 9-6140-200-14). Place batteries back in battery
boxes.
9.
Check engine coolant to ensure coolant has correct mixture for expected temperatures (WP 0020 00).
10.
Seal all openings in engine, including air intake, exhaust outlet, and crankcase breather tube, with Tape, pressure sensi-
11.
12.
Fill in DD Form 1397, Vehicles and Spare Engines, Processing and Deprocessing Record for Shipment, Storage and
Issue of, completely and attach to a conspicuous part of machine.
13.
Inflate tires to 36 psi (248 kPa) for front and 25 psi (172 kPa) for rear with dry air (TM 5-3805-290-10). Annotate air
pressure and/or if nitrogen was used on DA Form 2258, Depreservation Guide for Vehicles and Equipment.
PREPARATION FOR RETURN TO SERVICE FROM SHORT-TERM STORAGE
0208 00
1.
Inflate tires to 36 psi (248 kPa) for front and 25 psi (172 kPa) for rear with dry air (TM 5-3805-290-10).
2.
Remove tape from all engine openings, including air intake, exhaust outlet, and crankcase breather tube.
3.
If disconnected, connect battery cables (WP 0077 00).
4.
5.
6.
Start engine and perform machine warm-up (TM 5-3805-290-10). Verify proper operation of all gages, switches, and
lights.
7.
Operate machine without a load and check engine, transmission, brakes, steering, and electrical accessories for correct
PREPARATION FOR LONG-TERM STORAGE
0208 00
N OT E
Long-term storage is storage for more than 90 days.
1.
Thoroughly clean machine.
2.
3.
Perform Unit PMCS (WP 0019 00 and WP 0020 00).
4.
Schedule next PMCS on ULLS-G.
5.
Inspect machine for corrosion. Use touch-up paint where necessary to prevent rust (TB 43-0242, CARC Spot Painting).
6.
Where practical, store hydraulic cylinders in fully retracted position, which is normal locked/stored position for equip-
ment. Fill hydraulic systems to operating level (TM 5-3805-290-10). Coat exposed surfaces of hydraulic cylinder with
Grease, automotive and artillery, GAA (Item 22, WP 0206 00). Wrap Barrier material, grease proofed, flexible (Item 5,
Place a tag on cylinder requiring grease to be cleaned off exposed surface prior to use. This is necessary to prevent cyl-
inder seal from being damaged by contaminated grease.