AIR CLEANER HOUSING CLEANING AND INSPECTION
WARN I N G
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low-toxic material.
However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in well-ventilated
areas. Keep away from open flames and other sources of ignition. Failure to do so may result in injury or
death to personnel.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure when dry-
ing parts with compressed air. DO NOT direct compressed air against human skin. Make sure air stream is
directed away from user and other personnel in the area. To prevent injury, user must wear protective goggles
or face shield. Failure to follow this warning may result in injury to personnel.
1.
Clean all metal parts and surfaces with solvent cleaning compound.
2.
Clean all other parts with detergent and water solution.
3.
Dry parts with compressed air.
4.
Inspect all parts for wear, pitting, cracks, or corrosion and replace if necessary.
AIR CLEANER HOUSING INSTALLATION
00032 00
1.
Position air cleaner housing (6) on machine.
2.
Install two retaining clips (10), four washers (8), two mounting bolts (7), and nuts (9) on air cleaner housing (6).
3.
Connect air outlet hose (5) to air cleaner housing (6).
4.
Tighten hose clamp (4).
5.
Connect hose (2) to tube (3).
6.
Tighten clamp (1).
427-B0128
7.
Install air filter elements (TM 5-3805-290-10).
8.
Run engine until operating temperature is reached and verify correct operation (TM 5-3805-290-10).
9.
Shut down engine (TM 5-3805-290-10).
0032 00-3