TM 5-3805-290-23-2
FUSE, RELAY, AND CIRCUIT BREAKER REPLACEMENT - CONTINUED
0054 00
CIRCUIT BREAKER INSTALLATION
N OT E
Refer to figure 68 in RPSTL for all circuit breakers.
Table 4. Circuit Breaker Description Chart - Installation.
Component Name
Callout
Lamp circuit breaker
51
Auxiliary circuit breaker
59
Main circuit breaker
60
61
1.
Install circuit breaker (51), two washers (58), bolts (57), and nuts (56) on machine.
2.
Install two wiring connections (55), washers (54), bolts (53), and nuts (52) on circuit breaker (51).
3.
Install two covers (50) on circuit breaker (51).
4.
Perform step 1 for circuit breakers (61, 60, and 59).
427-B1956
5.
6.
Verify correct operation of electrical accessories and components (TM 5-3805-290-10).
0054 00-14