TM 5-3805-290-23-2
FUSE, RELAY, AND CIRCUIT BREAKER REPLACEMENT - CONTINUED
0054 00
VOLTAGE LOAD PROTECTION MODULE (VLPM) REMOVAL
0054 00
1.
Cut and discard tiedown strap (62).
2.
Remove bolt (63) and clamp (64) from bracket (65).
3.
Disconnect and remove VLPM (66) from machine.
VOLTAGE LOAD PROTECTION MODULE (VLPM) INSTALLATION
1.
Connect and position VLPM (66) on machine.
2.
Install clamp (64) and bolt (63) on bracket (65).
3.
Install new tiedown strap (62) around VLPM (66).
427-B2117
END OF WORK PACKAGE