TRANSMISSION MAGNETIC SCREEN SERVICE - CONTINUED
TORQUE CONVERTER OIL COOLER LINES REPLACEMENT - CONTINUED

Manual 2 Loader, Light, Scoop: 2.5 Cubic Yard Multipurpose (Mp) Clamshell Bucket, Diesel Engine Driven (Ded), 4-Wheel Drive Model 924G
Page Navigation
  285    286    287    288    289  290  291    292    293    294    295  
img
. . . . . . . . . . . . . . . . .
8
TM 5-3805-290-23-2
TORQUE CONVERTER OIL COOLER LINES REPLACEMENT
0085 00
THIS WORK PACKAGE COVERS
Removal, Cleaning and Inspection, Installation
INITIAL SETUP
Maintenance Level
Materials/Parts - Continued
Rag, wiping (Item 41, WP 0206 00)
Unit
Tag, marker (Item 54, WP 0206 00)
Tools and Special Tools
O-ring (12)
Tool kit, general mechanic's (Item 96, WP 0205 00)
Personnel Required
MOS 62B, Construction Equipment Repairer
Shop equipment, common no. 1 (Item 77, WP 0205
00)
References
TM 5-3805-290-10
Materials/Parts
Cap set, protective (Item 8, WP 0206 00)
Equipment Conditions
Remove right-side cover between cab and engine
Cleaning compound, solvent, type III (Item 9, WP
access door (WP 0110 00)
0206 00)
Transmission fluid drained (WP 0083 00)
Oil, lubricating, OEA-30, Arctic (Item 32, WP
0206 00)
Drawings Required
TM 5-3805-290-23P, Figures 72, 75, and 94
Oil, lubricating, OE/HDO-40 (Item 33, WP 0206
00)
Estimated Time to Complete Task
2.6 hr
Oil, lubricating, TO-4 (Item 36, WP 0206 00)
WARN I N G
When servicing this machine, performing maintenance, or disposing of hazardous materials, consult your
unit/local hazardous waste disposal center or safety office for local regulatory guidance. If further informa-
tion is needed, please contact The Army Environmental Hotline at 1-800-872-3845.
Lubricating/hydraulic oils used in the performance of maintenance can be very slippery. Immediately wipe up
any spills. Failure to follow this warning may result in injury to personnel.
To prevent injury to personnel, wear protective eye covering and gloves.
C AU T I O N
Wipe area clean around all connections to be opened during removal. Cap lines and hoses and plug open-
ings after removing lines. Contamination of system could result in premature failure.