• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
BRAKE ACCUMULATOR REPLACEMENT - CONTINUED
BRAKE ACCUMULATOR REPLACEMENT - CONTINUED

Manual 2 Loader, Light, Scoop: 2.5 Cubic Yard Multipurpose (Mp) Clamshell Bucket, Diesel Engine Driven (Ded), 4-Wheel Drive Model 924G
Page Navigation
  363    364    365    366    367  368  369    370    371    372    373  
img
TM 5-3805-290-23-2
BRAKE ACCUMULATOR REPLACEMENT - CONTINUED
0096 00
CHARGING - CONTINUED
N OT E
To ensure that nitrogen charge is correct, each brake accumulator piston must be at bottom of accumulator
cylinder. Nitrogen gas pressure varies with temperature. To obtain most accurate nitrogen charge, temper-
ature of each accumulator must be identical to air temperature around accumulators.
Table 1. Charging Pressure and Temperature Relationship for
Typical 500 psi (3,450 kPa) Accumulator.
TEMPERATURE F (C)
PRESSURE PSI (KPA)
20F
453 psi
(-7C)
(3,123 kPa)
462 psi
30F
(-1C)
(3,185 kPa)
472 psi
40F
(4C)
(3,254 kPa)
482 psi
50F
(10C)
(3,323 kPa)
491 psi
60F
(16C)
(3,385 kPa)
500 psi
70F
(21C)
(3,448 kPa)
509 psi
80F
(27C)
(3,509 kPa)
519 psi
90F
(32C)
(3,578 kPa)
528 psi
100F
(38C)
(3,640 kPa)
538 psi
110F
(43C)
(3,709 kPa)
547 psi
120F
(49C)
(3,771 kPa)
0096 00-7


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.