TM 5-3805-290-23-2
BRAKE ACCUMULATOR REPLACEMENT - CONTINUED
0096 00
CHARGING - CONTINUED
b.
Close valve (16) and open valve on nitrogen cylinder. Adjust screw (19) on regulator assembly until pressure gage
(20) is at correct charging pressure.
c.
Open valve (16) and charge brake accumulator. Then close valve. If pressure gage (14) and pressure gage (21),
show same reading and readings do not change, brake accumulator has correct charge.
11.
If pressure reading on gage (14) decreases, open valve (16) and allow more nitrogen to fill accumulator.
12.
Perform this procedure until pressure gage (14) and pressure gage (21) show same reading. Make sure neither reading
changes when valve (16) is closed.
13.
Close valve (16). Close valve on nitrogen cylinder.
14.
Turn valve (18) on chuck (15) outward in counterclockwise direction. Remove nitrogen fitting equipment.
15.
Perform this procedure for other brake accumulator.
END OF WORK PACKAGE
0096 00-9/(0096 00-10 Blank)