PILOT OIL ACCUMULATOR MAINTENANCE - CONTINUED
0126 00
TESTING AND CHARGING - CONTINUED
N OT E
Other end of hose assembly will remain open.
7.
Connect hose assembly (10) to nitrogen charging chuck (11) and Extension assembly (Item 31, WP 0205 00).
8.
Turn valve handle (12) on nitrogen charging chuck (11) counterclockwise. This will ensure nitrogen charging valve (9)
of pilot oil accumulator (2) will not be opened when nitrogen charging chuck is attached.
9.
Install nitrogen charging chuck (11) on nitrogen charging valve (9) of pilot oil accumulator (2).
10.
Place open end of hose assembly (10) away from work area.
11.
Turn valve handle (12) on nitrogen charging chuck (11) clockwise to fully open nitrogen charging valve (9). This will
release all compressed gas from pilot oil accumulator (2) through hose assembly (10).
12.
Remove nitrogen charging chuck (11) from nitrogen charging valve (9) of pilot oil accumulator (2).
13.
Install protective cap (8) on nitrogen charging valve (9).
427-B0784
427-B02056
0126 00-7