TM 5-3805-290-23-2
INTAKE MANIFOLD REPLACEMENT - CONTINUED
0162 00
REMOVAL - CONTINUED
6.
Remove atmosphere pressure sensor (13) from intake
manifold (8).
7.
Remove air temperature sensor (14) from intake mani-
fold (8).
427-B1361
CLEANING AND INSPECTION
WARN I N G
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low-toxic material.
However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in well-ventilated
areas. Keep away from open flames and other sources of ignition. Failure to do so may result in injury or
death to personnel.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure when dry-
ing parts with compressed air. DO NOT direct compressed air against human skin. Make sure air stream is
directed away from user and other personnel in the area. To prevent injury, user must wear protective goggles
or face shield. Failure to follow this warning may result in injury to personnel.
1.
Scrape all gasket material from mating surfaces.
CAU T I ON
Take care with solvent around sensors as damage may occur.
2.
Clean all parts and surfaces with solvent cleaning compound.
3.
Dry parts with compressed air.
4.
Inspect all parts for wear, pitting, cracks, or corrosion and replace if necessary.
5.
Inspect oil passages to ensure they are clean and unobstructed.
6.
If reusing original bolts, clean sealant off threads.
0162 00-3