• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
REFUELING AND FUEL SYSTEM PRIMING
ENGINE AIR PRECLEANER SERVICE AND AIR CLEANER SERVICE

Operators Manual For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  211    212    213    214    215  216  217    218    219    220    221  
img
. . .
TM 5-3805-291-10
REFUELING AND FUEL SYSTEM PRIMING - CONTINUED
0013 00
REFUELING - CONTINUED
7.
If necessary to remove strainer to facilitate cleaning, reach in with your fingers and pull strainer out of filler opening.
8.
Clean debris and reinstall strainer in filler opening.
N OT E
Fuel tank capacity is 106 gal. (404 L).
DO NOT overfill fuel tank. If fuel starts foaming from fuel tank, stop IMMEDIATELY to avoid fuel spillage.
Ensure any fuel spillage is cleaned up.
9.
Fill fuel tank with fuel. Use correct grade of fuel IAW expected temperature range of operation.
10.
Position filler cap in filler opening and turn black tab one quarter turn clockwise (to the right).
11.
Fold black tab down into green tab.
12.
Close rear access door.
FUEL SYSTEM PRIMING
0013 00
N OT E
If engine fails to start because loader
ran out of fuel, it may be necessary to
prime fuel system.
Fuel priming pump is located above
primary fuel filter on right side of
engine.
1.
Tilt hood (WP 0004 00).
2.
Turn fuel priming pump toggle switch to ON position
and operate pump for approximately 60 seconds. Turn
switch to OFF position.
427-C1675
3.
Start engine (WP 0005 00).
4.
Operate fuel priming pump for additional time if any of the following conditions exist:
a.
Engine continues to not start.
b.
Engine starts but continues to misfire or emit smoke.
5.
Lower hood (WP 0004 00).
END OF WORK PACKAGE
0013 00-2