Table 2. Electrical System Troubleshooting - Continued.
Table 2. Electrical System Troubleshooting - Continued.

Field Maintenance Manual 1 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  435    436    437    438    439  440  441    442    443    444    445  
img
TM 5-3805-291-23-1
TROUBLESHOOTING WITHOUT A DIAGNOSTIC CODE - CONTINUED
0008 00
Table 2. Electrical System Troubleshooting - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. Check backup alarm circuit for a short
1. If wiring harness is OK, go to Test 3.
4.
Backup Alarm Always Off.
to ground.
2. If there is a short in wiring harness,
- Continued.
(a) Wiring harness remains
short is between wire 321 BR (backup
disconnected from backup alarm.
alarm signal) and circuit with low
(b) Turn engine start switch and
resistance measurement. Replace
battery disconnect switch to OFF
wiring harness in question (WP 0195
position (TM 5-3805-291-10).
00 thru WP 0201 00).
(c) Disconnect wiring harness
connectors J1 and J2 from
powertrain ECM (WP 0063 00).
(d) Bypass switch side of backup
alarm relay with jumper wire.
8
(e) At wiring harness connector J2,
measure resistance from J1-12
(backup alarm signal) to all
possible sources of ground. Check
resistance to all other connectors
used in ECM harness connector.
0008 00-34