FORWARD HIGH SPEED LOCKOUT PROGRAM - CONTINUED
REVERSE HIGH SPEED LOCKOUT PROGRAM - CONTINUED

Field Maintenance Manual 1 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  900    901    902    903    904  905  906    907    908    909    910  
img
. .
TM 5-3805-291-23-1
POWERTRAIN TESTS, INSPECTIONS, AND ADJUSTMENTS - CONTINUED
0014 00
REVERSE HIGH SPEED LOCKOUT PROGRAM
0014 00
N OT E
This calibration procedure can be performed without running engine.
1.
Turn engine start switch to ON position (TM 5-3805-291-10).
N OT E
Power to ECM must be cycled for calibration to take effect.
2.
Connect MSD to diagnostic connector (WP 0005 00).
3.
Select "Transmission" (1) from "ECM Selector" menu and click "OK" (2).
427-C0714
0014 00-8