TM 5-3805-291-23-1
POWERTRAIN TESTS, INSPECTIONS, AND ADJUSTMENTS - CONTINUED
0014 00
RIDE CONTROL CONFIGURATION PROGRAM
0014 00
N OT E
This calibration procedure can be performed without running engine.
1.
Turn engine start switch to ON position (TM 5-3805-291-10).
2.
N OT E
Power to ECM must be cycled fo calibration to take effect.
r
MSD will allow activation speedfor ride control to be adjusted in 0.6 mph (1 km/h) increments.
Engagement speed may be adjusted between 1.2 mph (2 km/h) and 14.3 mph (23 km/h). Factory
setting for activation speed (forward) is 6.0 mph (9.7 km/h) and for activation speed (reverse) is
2.0 mph (3.2 km/h).
3.
Select "Transmission" (1) from "ECM Selector" menu and click "OK" (2).
427-C0714