REVERSE HIGH SPEED LOCKOUT PROGRAM - CONTINUED
RIDE CONTROL CONFIGURATION PROGRAM - CONTINUED

Field Maintenance Manual 1 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  905    906    907    908    909  910  911    912    913    914    915  
img
. .
TM 5-3805-291-23-1
POWERTRAIN TESTS, INSPECTIONS, AND ADJUSTMENTS - CONTINUED
0014 00
RIDE CONTROL CONFIGURATION PROGRAM
0014 00
N OT E
This calibration procedure can be performed without running engine.
1.
Turn engine start switch to ON position (TM 5-3805-291-10).
2.
Connect MSD to diagnostic connector (WP 0005 00).
N OT E
Power to ECM must be cycled fo calibration to take effect.
r
MSD will allow activation speedfor ride control to be adjusted in 0.6 mph (1 km/h) increments.
Engagement speed may be adjusted between 1.2 mph (2 km/h) and 14.3 mph (23 km/h). Factory
setting for activation speed (forward) is 6.0 mph (9.7 km/h) and for activation speed (reverse) is
2.0 mph (3.2 km/h).
3.
Select "Transmission" (1) from "ECM Selector" menu and click "OK" (2).
427-C0714
0014 00-13