Field Maintenance Manual 1 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  984    985    986    987    988  989  990    991    992    993    994  
img
TM 5-3805-291-23-1
BRAKE SYSTEM TESTS, INSPECTIONS, AND ADJUSTMENTS - CONTINUED
0015 00
HYDRAULIC FAN SPEED TEST AND ADJUSTMENT - CONTINUED
Hydraulic Fan Speed (Testing and Adjusting) - Continued
N OT E
Procedure on screen may specify different value for fan speed. DO NOT use this value. Set the fan speed to
1,200 50 rpm.
13.
Continue running machine at high idle.
14.
Use multi tach to measure fan speed.
N OT E
Increasing the current will decrease the fan speed Decreasing the current will increase the fan
.
speed.
Adjust current for fan solenoid by usin arrows at bottom of screen (43).
g
15.
Adjust current until fan speed is 1,200 50 rpm.
16.
When fan speed has been set properly, click "Next" (42).
427-C0626