Hydraulic Fan Speed (Testing and Adjusting) - Continued
Hydraulic Fan Speed (Testing and Adjusting) - Continued

Field Maintenance Manual 1 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  986    987    988    989    990  991  992    993    994    995    996  
img
TM 5-3805-291-23-1
BRAKE SYSTEM TESTS, INSPECTIONS, AND ADJUSTMENTS - CONTINUED
0015 00
HYDRAULIC FAN SPEED TEST AND ADJUSTMENT - CONTINUED
Hydraulic Fan Speed (Testing and Adjusting) - Continued
18.
Continue running machine at high idle.
19.
Use multi tach to measure fan speed.
N OT E
Increasing the current will decrease the fan speed Decreasing the current will increase the fan
.
speed.
Adjust current for fan solenoid by usin arrows at bottom of screen (43).
g
Procedure on screen may specify different valuefor fan speed. DO NOT use this value. Set fan
speed to 500 50 rpm.
427-C0626-1
0015 00-35