Hydraulic Fan Speed (Testing and Adjusting) - Continued
STEERING SYSTEM TESTS, INSPECTIONS, AND ADJUSTMENTS

Field Maintenance Manual 1 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  988    989    990    991    992  993  994    995    996    997    998  
img
.
TM 5-3805-291-23-1
BRAKE SYSTEM TESTS, INSPECTIONS, AND ADJUSTMENTS - CONTINUED
0015 00
HYDRAULIC FAN SPEED TEST AND ADJUSTMENT - CONTINUED
Hydraulic Fan Speed (Testing and Adjusting) - Continued
22.
After setting minimum fan speed, click "Finish" to save calibration values.
23.
With assistance, return to low idle and stop engine (TM 5-3805-291-10).
24.
Exit MSD.
25.
Disconnect MSD from diagnostic connector (WP 0005 00).
26.
Remove photo pickup (24) and magnetic base (25) from fan guard assembly (26).
427-C0617
27.
Install side covers (WP 0135 00).
28.
Close hood (TM 5-3805-291-10)
WARN I N G
Before operating the machine, secure steering frame lock in stowed position. DO NOT operate machine
with steering frame lock connected. Failure to lock steering frame lock into stowed position before operat-
ing can result in loss of steering and injury or death to personnel.
29.
Secure steering frame lock in stowed position (TM 5-3805-291-10).
END OF WORK PACKAGE