JOYSTICK CONTROL POSITION SENSOR CALIBRATION WITH MSD - CONTINUED
JOYSTICK CONTROL POSITION SENSOR CALIBRATION WITH MSD - CONTINUED

Field Maintenance Manual 1 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  1014    1015    1016    1017    1018  1019  1020    1021    1022    1023    1024  
img
TM 5-3805-291-23-1
HYDRAULIC SYSTEM TESTS, INSPECTIONS, AND ADJUSTMENTS - CONTINUED
0017 00
JOYSTICK CONTROL POSITION SENSOR CALIBRATION WITH MSD - CONTINUED
N OT E
MSD screen will be divided into three display areas. Top section of screen will be used to display important
status parameters that are monitored during calibration. Middle section of screen displays information
about calibration procedure. Bottom section of screen displays step-by-step instructions for calibration.
Step that currently needs performing will be in bold text. All other steps will be displayed in gray text.
8.
Click "Next" (7) to begin calibration. Check mark button will be placed to left of completed step and next step will be
highlighted in bold text. After successful completion of step, you may need to click "Next" to begin the following step.
The following steps listed in bottom section of screen until calibration procedure is complete.