Calibration Problems - Continued
JOYSTICK CONTROL POSITION SENSOR CALIBRATION WITH MSD

Field Maintenance Manual 1 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  1009    1010    1011    1012    1013  1014  1015    1016    1017    1018    1019  
img
TM 5-3805-291-23-1
HYDRAULIC SYSTEM TESTS, INSPECTIONS, AND ADJUSTMENTS - CONTINUED
0017 00
CALIBRATION - CONTINUED
Calibration Problems - Continued
Problem 13: After calibration is complete, the lift lowers too fast when the implement lever is not in the detent position.
The lift speed is uncontrollable when the implement lever is not in the detent position.
Probable Cause - Maximum lower modulation current is too high.
Corrective Action - Verify maximum lower speed according to the directions in Maximum Modulation Current to Sole-
noid Valves Calibration in this work package.
Problem 14: After calibration is complete, the lift linkage lowers too slowly when the control lever is not in the FLOAT
position.
Probable Cause - Maximum lower modulation current is too low.
Corrective Action - Verify maximum lower speed according to the directions in Maximum Modulation Current to Sole-
noid Valves Calibration in this work package.
0017 00-5