TM 5-3805-291-23-1
THERMOSTAT REPLACEMENT - CONTINUED
0044 00
INSTALLATION
1.
Lubricate new O-rings with antifreeze and install two
new O-rings (10) on tube (11) and thermostat (9).
2.
Install thermostat (9) in housing (7).
3.
Install new seal (8) in housing (7).
4.
Install housing (7) and four bolts (6).
5.
Connect hose (5) and tighten two clamps (4).
427-C0379
6.
Top off cooling system (TM 5-3805-291-10).
7.
Run engine until normal operating temperature is
reached and coolant level stabilizes (TM 5-3805-291-
10).
8.
Shut down engine (TM 5-3805-291-10).
9.
Check for leaks.
10.
Install left side cover (1) on machine.
427-C1925
END OF WORK PACKAGE
0044 00-4